Building type 1

Classroom pavilion

Daylit classrooms of around 60 m², grouped around a corridor with sanitary and staff facilities. Built in the factory as 3.0 × 12.0 m modules, assembled on site, and designed to be taken apart again.

A prefabricated module with windows lifted by crane
Classrooms
2–24
Classroom size
approx. 60 m² net
Storeys
1–3
Energy levels
3 options

Typical plan

Four classrooms on the ground floor.

Indicative layout for a single-storey pavilion of four classrooms. Each classroom spans two modules; the corridor and staff zone are built into the module depth.

Classroom 1approx. 60 m²Classroom 2approx. 60 m²Classroom 3approx. 60 m²Classroom 4approx. 60 m² Sanitary+ technical Corridor 1.8 m Staff room Coats, storage and entrance Indicative, not to scale. Dashed lines mark module joints.

Specifications

Demonstration values

Classroom pavilion specifications
Module size (gross)3.0 × 12.0 m, approx. 36 m²
Clear ceiling heightapprox. 3.0 m in classrooms
Classroomapprox. 60 m² net, two modules
Storeys1–3, stair core from two storeys; lift as option
StructureSteel frame with timber-based infill panels
FacadeFibre-cement boards or timber cladding, colour by choice
VentilationBalanced ventilation with heat recovery (enhanced and near-zero levels)
HeatingAir-to-water heat pump (enhanced and near-zero levels)
FoundationGround screws or concrete strip, depending on soil survey
RelocationDismantled per module; services disconnected at module joints

Values are demonstration figures for a fictional company. Final specifications follow from the programme of requirements, the site and the permit route.

Energy levels

Choose per project

Standard temporary-use

For short terms where the permit route allows a temporary-use envelope. Lowest initial cost.

Enhanced

Better insulation, heat pump and balanced ventilation – aimed at a comfortable indoor climate for longer terms and at permanent-use requirements.

Near-zero ambition

Enhanced level plus a PV-ready roof and extra airtightness, for boards with a near-zero ambition. Compliance is checked per project, never assumed.

Concrete courtyard with glass facades and young trees

Questions boards ask

Frequently asked

Does a pavilion need a permit?

Yes, in almost every case. Whether a temporary or permanent permit applies depends on the intended term and local rules; we prepare the drawings and calculations for either route.

Can we extend it later?

Yes. Modules are added at the end of the corridor or as an extra storey, if the structure and foundation were dimensioned for it – which we check at the start.

What happens at the end of the lease?

The pavilion is dismantled per module and refurbished for its next site. The site is returned in the agreed state.